NADCAP Accredited · AS9100D Certified · ITAR Registered

Every Layer
Passes.
Every Time.

Mil-spec hard anodizing, chemical conversion coatings, and CARC paint systems for the components warfighters depend on. DCMA-accepted. NADCAP-accredited. No exceptions.

MIL-A-8625 Type I/II/IIIMIL-DTL-5541MIL-PRF-23377MIL-DTL-64159AMS 2469AMS 2470
NADCAP Accredited·AS9100D Certified·ITAR Registered·MIL-A-8625·MIL-DTL-5541·MIL-PRF-23377·MIL-DTL-64159·Hard Anodize Type III·CARC Paint Systems·Chemical Conversion Coating·DCMA Accepted·Zero Major NCs — 4 Consecutive AS9100D Cycles·NADCAP Accredited·AS9100D Certified·ITAR Registered·MIL-A-8625·MIL-DTL-5541·MIL-PRF-23377·MIL-DTL-64159·Hard Anodize Type III·CARC Paint Systems·Chemical Conversion Coating·DCMA Accepted·Zero Major NCs — 4 Consecutive AS9100D Cycles·
Checkpoint 01

Process Capabilities
& Spec Matrix

Every process below is actively maintained in our NADCAP scope. Filter by process family to verify coverage against your drawing requirements.

Anodize

4 processes
ProcessGoverning SpecSubstrateTypical ThicknessApplication Notes
Type I — Chromic Acid AnodizeMIL-A-8625 Type IAluminum0.00002–0.0001"Fatigue-sensitive airframe components
Type II — Sulfuric Acid AnodizeMIL-A-8625 Type IIAluminum0.0002–0.001"General corrosion protection
Type III — Hard AnodizeMIL-A-8625 Type IIIAluminum0.001–0.002"Wear-critical surfaces, actuators, hydraulic housings
Titanium AnodizeAMS 2487 / AMS 2488TitaniumN/AStructural fasteners, rotor systems

Conversion

4 processes
ProcessGoverning SpecSubstrateTypical ThicknessApplication Notes
Chromate Conversion — Class 1AMIL-DTL-5541 Class 1AAluminum<0.00001"Conductive, full corrosion protection
Chromate Conversion — Class 3MIL-DTL-5541 Class 3Aluminum<0.00001"Low electrical resistance, radar housings
Trivalent Chromate (TCP)MIL-DTL-5541 / SAE AMS2473Aluminum<0.00001"RoHS-compliant, EH&S preferred
PassivationAMS 2700 / ASTM A967Stainless Steel / CRESN/AMissile hardware, guidance assemblies

CARC Paint

3 processes
ProcessGoverning SpecSubstrateTypical ThicknessApplication Notes
CARC Epoxy PrimerMIL-PRF-23377 Class CAll metals0.6–0.9 mils DFTPre-prime for topcoat adhesion
CARC Polyurethane TopcoatMIL-DTL-64159 Type IIAll metals1.5–2.5 mils DFTVehicle subframes, armored panels
Primer-Only SystemMIL-PRF-85582Aluminum0.6–0.9 mils DFTAerospace structural components

Specialty

3 processes
ProcessGoverning SpecSubstrateTypical ThicknessApplication Notes
Black OxideMIL-DTL-13924 Class 1Steel<0.00001"Optical mounts, weapon components
Electroless NickelAMS 2404 / MIL-C-26074Steel / Al0.0005–0.001"Wear + corrosion, guidance bodies
Zinc PhosphateMIL-DTL-16232 Type ZSteel0.0001–0.0003"Paint adhesion base, depot MRO

Don't see your spec requirement?

Submit your drawing for a rapid process feasibility review — 48-hour response.

Request Qualification Package
Checkpoint 02

Certifications &
Audit Status

Live accreditation status — not a logo wall. Every card below reflects the current audit cycle, scope, and surveillance record your quality team needs to verify without picking up the phone.

NADCAP
ACTIVE

National Aerospace and Defense Contractors Accreditation Program

98.4%

Latest result

Scope

Chemical Processing — AC7108

Last Audit

Nov 2025

Next Surveillance

May 2026

Accrediting Body

Performance Review Institute

Merit Note

Merit Accreditation (18-month interval)

Anodizing (Type I, II, III)Chemical Conversion CoatingPassivationElectroless Nickel
AS9100D
ACTIVE

Aerospace Quality Management System

0 Major NCs

Latest result

Scope

Design, Manufacture, and Processing of Aerospace Components

Last Audit

Sep 2025

Next Surveillance

Sep 2026

Accrediting Body

DNV Registrar

Merit Note

Zero major nonconformances — 4 consecutive cycles

Quality ManagementProcess ControlDocument ControlCorrective Action
ITAR
REGISTERED

International Traffic in Arms Regulations Registration

Compliant

Latest result

Scope

Defense Articles — USML Categories VIII, XI, XV

Last Audit

Jan 2026

Next Surveillance

Jan 2027

Accrediting Body

U.S. Dept. of State, DDTC

Merit Note

Continuous registration since 2009

Access control protocolsForeign national screeningExport licensing complianceSecure document handling
ISO 9001:2015
ACTIVE

Quality Management System

0 Major NCs

Latest result

Scope

Surface Treatment and Metal Finishing Operations

Last Audit

Sep 2025

Next Surveillance

Sep 2026

Accrediting Body

DNV Registrar

Merit Note

Co-certified with AS9100D audit

Customer focusRisk-based thinkingProcess approachContinual improvement

Secondary Conversion Path

Download Our NADCAP Scope of Accreditation

Full accreditation certificate + approved process listing. Name and work email only.

Download Scope PDF
Checkpoint 03

Quality System
In-Process Verification

Five verification checkpoints from material receipt to shipment. Click any step to see testing methodology, acceptance criteria, and the data your quality engineer will ask for.

Ready to qualify us as an approved processor?

Request the full supplier qualification package including our AS9100D certificate, NADCAP scope, and approved process listing.

Request Qualification Package
0%

On-Time Delivery

Rolling 12-month average

0.00%

Lot Rejection Rate

Internal first-pass yield

0yr

NADCAP Continuity

Uninterrupted accreditation

0+

Defense Part Numbers

Processed annually

MIL-A-8625MIL-DTL-5541MIL-PRF-23377MIL-DTL-64159AMS 2469AMS 2470AMS 2404AS9100DNADCAPITARISO 9001:2015ASTM B244ASTM D4541AS9102BMIL-A-8625MIL-DTL-5541MIL-PRF-23377MIL-DTL-64159AMS 2469AMS 2470AMS 2404AS9100DNADCAPITARISO 9001:2015ASTM B244ASTM D4541AS9102BMIL-A-8625MIL-DTL-5541MIL-PRF-23377MIL-DTL-64159AMS 2469AMS 2470AMS 2404AS9100DNADCAPITARISO 9001:2015ASTM B244ASTM D4541AS9102B
Checkpoint 04

Prime Contractor
Field Reports

"Anodize is the only processor on our ASL that has never missed a DCMA source inspection. Their traveler documentation package comes in cleaner than most of our internal shops."

Marcus T.

Director of Supply Chain Quality

Tier-1 Defense Integrator

Ground Vehicle Electronics Program

"We pulled them into a critical path situation on a radar housing — 72-hour turnaround on Type III with full test documentation. They executed without a single NCR. That's the kind of supplier you build a program around."

Jennifer W.

Senior Program Manager

Aerospace Prime

Airborne EW System

"Their ITAR protocols are tighter than some classified facilities I've audited. We had zero findings during our annual supplier audit. The bath chemistry records alone were more thorough than our own internal requirements."

David K.

Supplier Quality Engineer

Missile Systems Division

Precision Guidance Package
Checkpoint 05

Initiate Supplier
Qualification

Submit your requirements below. A process engineer will respond within one business day with our full qualification package — certificates, scope of accreditation, and approved process listing formatted for your supplier management system.

Primary Path — Full Qualification Package

PDF, DWG, DXF, or TIF · Max 25MB · ITAR-safe transfer

ITAR-controlled information handled in accordance with 22 CFR Part 120–130. Response within 1 business day.

Secondary Path

Download NADCAP Scope of Accreditation

Full accreditation certificate + approved process listing. For engineers building their approved processor shortlist.

Direct Contact

Supplier Quality Desk

quality@anodize.com

Program Office

+1 (619) 555-0284

Facility Hours

Mon–Fri 0500–2100 PST